Dual, triple and megasonic: what's the difference?
Dual and triple describe available operating modes; megasonic identifies a different high-frequency cleaning approach. None of these labels alone establishes the usable settings, switching method or suitability for your parts.
Three checks
Ask how each mode is implemented
A multi-frequency system may provide different modes for different process stages, but the label does not explain how the generator operates them. Ask whether the approved equipment switches sequentially, uses a particular control arrangement or requires separate settings. Do not assume that several signals can simply be applied together to the same component. A useful acceptance package includes the paired generator description, a mode table and the operating procedure. Each mode needs its own documented limits. A catalogue name can identify a discussion candidate, but it cannot replace that equipment-level information.
Do not interpret megasonic as an absence of cavitation
Megasonic cleaning should not be described as universally cavitation-free or automatically harmless to delicate structures. The liquid, gas condition and acoustic field influence the process. Define the contamination and the damage criteria before discussing a candidate. For fine structures, inspection must show both removal of unwanted material and preservation of the part. A clean-looking surface alone may not answer the question. Public descriptions of other manufacturers’ equipment explain general principles; they do not supply approved operating limits for Sunnytec components or prove that a particular assembly is suitable.
Match the process stage and the equipment together
Coarse cleaning, finishing and particle-control tasks can require different evaluation routes. Describe each stage separately instead of asking one label to cover every requirement. Include workpiece material, cleaning chemistry, fixture arrangement and tank construction in the request. The engineer can then review the transducer category, generator interface and installation conditions as a package. Exact operating bands, power settings and process durations remain subject to the approved specification. Do not extract unconfirmed settings from the numbers in a product name or transfer a recipe from a different bath without qualification.
Where this does not apply
These categories are not permission to mix an arbitrary generator with an arbitrary transducer. Megasonic cleaning is also not the default answer for every precision part. Sensitive coatings, fine structures and changes in chemistry require a process-specific assessment. Where cleanliness is linked to a regulated end use, the responsible equipment or process owner must define the qualification. This page makes no claim of sterilization, medical suitability or product-level certification from the choice of an acoustic technology.
How to verify
Request the approved operating conditions for every candidate mode and prepare a common inspection plan. Use representative samples, record the cleaning result and damage assessment, and check that the specified mode transition works as intended. Change variables only within the agreed trial plan and preserve the sequence of operations. When a mode is accepted, record the generator, mounting configuration and process conditions alongside it. The resulting document should identify a reproducible setup rather than merely stating that a dual-frequency, triple-frequency or megasonic product was selected. Include the cleaning stage and the reason for switching modes in the work instruction. Operators should be able to reproduce the accepted sequence without interpreting a product name or guessing which setting was used during the trial.