Buyer questions

Selection and troubleshooting answers with specification boundaries.

Selection

  • Which should I choose, 40 kHz or 80 kHz?

    Choose by contamination, surface tolerance and measured cleaning results, not frequency alone. Treat the frequencies in this question as comparison conditions; approved model limits remain subject to the approved specification.

  • 28 kHz vs 40 kHz at 60 W: what actually changes?

    The same stated power does not make two cleaning systems equivalent. Compare the frequency, assembled transducer, generator and loaded tank together; the values in this question are not an approved Sunnytec rating.

  • Dual, triple and megasonic: what's the difference?

    Dual and triple describe available operating modes; megasonic identifies a different high-frequency cleaning approach. None of these labels alone establishes the usable settings, switching method or suitability for your parts.

  • How much ultrasonic power does my tank need?

    Tank area alone cannot determine the required power. Define the power measurement, radiating surfaces, liquid depth and loading, then validate the assembled system. Numerical sizing remains subject to the approved specification.

  • How do I match transducer impedance to the generator?

    Match the measured impedance and phase response of the installed load to the generator requirements. A single resistance reading is insufficient; permissible values and test conditions remain subject to the approved specification.

  • Bottom-mounted or side-mounted: which one?

    Choose the mounting surface around the workpiece, obstruction and tank structure, then verify the loaded result. Neither bottom nor side mounting guarantees uniform cleaning on its own.

Troubleshooting and testing

  • How do I test whether a transducer is still good?

    Use documented visual and electrical checks together. Sound or a single reading cannot establish that a transducer is good; compare results under the specified conditions against its approved acceptance record.

  • Why is my transducer impedance above spec?

    First exclude measurement and connection differences, then investigate assembly or component damage. High impedance is a symptom, not a diagnosis; compare against the approved limit under the required conditions.

  • How can I tell if the transducer has debonded?

    Local cleaning loss or a changed sound can suggest a bond problem, but neither confirms it. Review the installation and use an approved inspection method before concluding that the transducer has debonded.

  • What does a drop in capacitance mean?

    A lower capacitance reading calls for a controlled comparison, not an immediate diagnosis of ageing or cracking. First reproduce the specified measurement conditions, then assess any confirmed change against the approved acceptance record.

  • Why does the resonant frequency drift?

    Review temperature, loading and assembly changes before calling a frequency shift a fault. Compare the same resonant mode under specified conditions; acceptable variation remains subject to the approved specification.

  • Cleaning performance dropped — how do I troubleshoot?

    Check liquid temperature, level, degassing, generator, transducer and tank in that order. Record changes before replacing parts or increasing power, and use the approved process as the comparison baseline.