Which should I choose, 40 kHz or 80 kHz?
Choose by contamination, surface tolerance and measured cleaning results, not frequency alone. Treat the frequencies in this question as comparison conditions; approved model limits remain subject to the approved specification.
Three checks
Define what has to come off
Separate loose particles, oil films and polishing residues in the request. Describe where contamination remains and how cleanliness will be judged. Lower-frequency cleaning can produce more vigorous cavitation, but chemistry and access to the surface still matter. Do not infer a removable particle size from the frequency printed on a quotation. A useful comparison records the starting contamination, the cleaning medium and the inspection method before a candidate is chosen. Ask whether the trial removes the actual residue without creating a different defect. The acceptance criterion is the inspected part, not the apparent activity at the liquid surface.
Give delicate surfaces their own acceptance check
A higher-frequency process can be a candidate for fine structures and sensitive finishes. That is a reason to test it, not permission to release it for production. Identify the vulnerable coating, edge, hole or bonded feature before the trial. Photograph the same inspection locations before and afterwards, using a consistent method. Record cleaning performance separately from surface damage so that an attractive finish does not conceal an unacceptable change. If the part has hidden features, agree how those will be checked. The operating frequency and permitted conditions for a Sunnytec component remain subject to the approved specification.
Compare the complete tank arrangement
Tank-bottom area is useful information about a proposed installation, but it is not a complete power-sizing rule. Supply the liquid depth, basket arrangement, workpiece loading and active radiating surfaces as well. Establish whether a quoted power describes electrical input, generator output or a separately measured acoustic quantity. An area-based comparison is meaningful only when its definitions and test conditions match. Do not treat a value expressed per unit area as interchangeable with one expressed per unit volume. Have the equipment engineer document the power basis and verify the loaded system before accepting a transducer arrangement.
Where this does not apply
This comparison is for selecting candidates for a cleaning task. It does not authorize changing a validated production recipe. A change in liquid, workpiece material, fixture or loading can invalidate a previous result. Where the equipment supplier specifies a qualified frequency, obtain approval before changing it. The guidance also does not transfer directly to welding stacks or atomizing elements. Those applications have different mechanical and electrical requirements and need their own acceptance plan.
How to verify
Use representative contaminated parts and compare candidate recipes only within the equipment supplier’s approved operating conditions. Keep the liquid preparation, loading and inspection procedure comparable, then record both cleanliness and surface condition. Include the tank drawing and the actual recipe in the trial record. Ask the technical team to identify which conditions can be transferred into the approved specification. If a comparison needs a setting outside the permitted operating envelope, stop and obtain a revised test plan rather than improvising a more aggressive trial. Keep the inspection images with the sample identification, including unsuccessful trials. This helps the team distinguish a genuine frequency effect from a different contamination level or a changed fixture position when the results are reviewed later.